id
stringlengths
12
16
title
stringlengths
6
140
description
stringlengths
76
139k
cpes
listlengths
0
0
cvss_v4_0
null
cvss_v3_1
float64
2.5
10
cvss_v3_0
float64
1.9
10
cvss_v2_0
null
ICSA-23-229-01
ICONICS and Mitsubishi Electric Products
A denial of service and potential crash vulnerability due to a buffer overrun condition exists in the OpenSSL library used in the ICONICS Suite. This vulnerability is in the X.509 certificate name constraint checking. A denial-of-service vulnerability due to a buffer overrun condition exists in the OpenSSL library used...
[]
null
null
5.9
null
ICSA-22-249-01
Triangle Microworks Libraries
The TMW IEC 61850 Library and TMW 60870-6 (ICCP/TASE.2) Library are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition.CVE-2022-38138 has been assigned t...
[]
null
null
7.5
null
ICSA-24-235-04
Avtec Outpost 0810
Avtec Outpost stores sensitive information in an insecure location without proper access controls in place. Avtec Outpost uses a default cryptographic key that can be used to decrypt sensitive information
[]
null
7.5
null
null
ICSA-22-167-15
Siemens Teamcenter Active Workspace
A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious code by tricking users into accessing a malicious link.
[]
null
6.1
null
null
ICSA-22-235-07
Hitachi Energy RTU500
This vulnerability exists in the HCI Modbus TCP function in affected product versions. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. There is a lack of flood con...
[]
null
null
7.5
null
ICSA-22-069-12
Siemens RUGGEDCOM ROS
Improper neutralization of special characters on the web server configuration page could allow an attacker, in a privileged position, to retrieve sensitive information via cross-site scripting. A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sens...
[]
null
7.5
null
null
ICSA-19-059-01
PSI GridConnect Telecontrol
The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.CVE-2019-6528 has been assigned to this vulnerability. A CVSS v3 base score of 8.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N).
[]
null
null
8.5
null
ICSA-20-252-05
Siemens Siveillance Video Client
In environments where Windows NTLM authentication is enabled the affected client application transmits usernames to the server in cleartext. This could allow an attacker in a privileged network position to obtain valid adminstrator login names and use this information to launch further attacks.
[]
null
5.3
null
null
ICSA-19-353-01
Moxa EDS Ethernet Switches
PROFINET DCE-RPC diagnostic packets can cause the device to enter a denial-of-service condition.CVE-2019-19707 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-18-081-02
Beckhoff TwinCAT
Several kernel drivers lack proper validation of user-supplied pointer values. An attacker who is able to execute code on the target may be able to exploit this vulnerability to obtain SYSTEM privileges. CVE-2018-7502 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vec...
[]
null
null
7.8
null
ICSA-23-012-08
Siemens S7-1500 CPU devices
Affected devices do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot image of the device and execute arbitrary code.
[]
null
4.6
null
null
ICSA-22-104-03
Red Lion DA50N
Authorized users may install a maliciously modified package file when updating the device via the web user interface. The user may inadvertently use a package file obtained from an unauthorized source or a file that was compromised between download and deployment.CVE-2022-26516 has been assigned to this vulnerability. ...
[]
null
null
4.6
null
ICSA-24-051-03
Mitsubishi Electric Electrical discharge machines
Remote code execution vulnerability due to Microsoft Message Queuing service on Microsoft Windows exists in electrical discharge machines.
[]
null
9.8
null
null
ICSA-20-343-04
Schneider Electric Modicon M221 Programmable Logic Controller
An inadequate encryption strength vulnerability exists that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.CVE-2020-7565 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been...
[]
null
null
3.3
null
ICSA-22-326-05
Moxa Multiple ARM-Based Computers
The affected devices and versions of Moxa's ARM-based computers have an execution with unnecessary privileges vulnerability, which could allow an attacker with user-level privileges to gain root privileges.CVE-2022-3088 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS v...
[]
null
null
7.8
null
ICSA-17-215-01
Schneider Electric Pro-face GP-Pro EX
An attacker is able to force the process to load an arbitrary DLL and execute arbitrary code in the context of the process.CVE-2017-9961 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:C/C:N/I:H/A:H).
[]
null
null
7.2
null
ICSMA-18-165-01
Natus Xltek NeuroWorks
A specially-crafted packet may be able to cause an out-of-bounds read, which may result in a denial-of-service condition.CVE-2017-2852 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). An attacker may cause a buffer...
[]
null
null
10
null
ICSA-24-053-01
Delta Electronics CNCSoft-B DOPSoft
The affected product insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.
[]
null
7.8
null
null
ICSA-24-226-05
Rockwell Automation DataMosaix Private Cloud
An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify ...
[]
null
9.1
null
null
ICSMA-23-047-01
BD Alaris Infusion Central
Alaris Infusion Central versions 1.1-1.3.2 may contain a recoverable password after installation, which could allow an attacker to disclose or tamper with resident personal data. Patient health data is not stored in the database, although some side installations may choose to store personal data. CVE-2022-47376 has bee...
[]
null
7.3
null
null
ICSA-20-308-01
WAGO Series 750-88x and 750-352 (Update A)
An attacker can execute a denial-of-service attack by sending a series of maliciously constructed packets to HTTP(S) Ports 80/443, which may cause the device to crash.CVE-2020-12516 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S...
[]
null
null
7.5
null
ICSA-23-012-04
Panasonic Sanyo CCTV Network Camera
Panasonic Sanyo CCTV Network Cameras versions 1.02-05 and 2.03-0x are vulnerable to CSRFs that can be exploited to allow an attacker to perform changes with administrator level privileges.-CVE-2022-4621 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV...
[]
null
null
7.5
null
ICSA-23-047-07
Siemens TIA Project-Server formerly known as TIA Multiuser Server
Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path.
[]
null
6.7
null
null
ICSA-21-334-03
Delta Electronics CNCSoft
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.CVE-2021-43982 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-23-012-01
Sewio RTLS Studio
Sewio's Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application's database. This could allow a remote attacker to login to the database with unrestricted access.-CVE-2022-45444 has been assigned to this vulnerability. A CV...
[]
null
null
5.5
null
ICSA-23-257-06
Siemans WIBU Systems CodeMeter
In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To exploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured a...
[]
null
9
null
null
ICSA-19-099-02
Siemens Spectrum Power 4.7
An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vul...
[]
null
null
10
null
ICSA-22-132-02
Mitsubishi Electric MELSOFT iQ AppPortal
Apache HTTP Server Versions 2.4.0 to 2.4.46 allow unprivileged local users to stop httpd on Windows.CVE-2020-13938 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H). In Apache HTTP Server Versions 2.4.0 to 2.4.46 a spe...
[]
null
null
7.5
null
ICSA-20-324-02
Paradox IP150 (Update A)
The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arbitrary code.CVE-2020-25189 has been assigned to these vulnerabilities. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/...
[]
null
null
8.8
null
ICSA-19-239-01
Delta Controls enteliBUS Controllers
The affected products are vulnerable to a buffer overflow condition due to the lack of input validation, which may allow an attacker to remotely execute arbitrary code.CVE-2019-9569 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S...
[]
null
null
9.8
null
ICSA-21-336-04
Hitachi Energy RTU500 series BCI
An issue exists in the BCI IEC 60870-5-104 function included in the affected products. If BCI IEC 60870-5-104 is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the affected product, causing it to reboot. This vulnerability is caused by the validation error ...
[]
null
null
7.5
null
ICSA-18-030-02
Siemens TeleControl Server Basic
An attacker with network access to Port 8000/TCP could bypass the authentication mechanism gaining access to limited information. CVE-2018-4835 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). An authenticated attack...
[]
null
null
5.3
null
ICSA-22-242-10
PTC Kepware KEPServerEX (Update A)
Specifically crafted OPC UA messages transmitted to the server could allow an attacker to crash the server and leak data. CVE-2022-2848 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H). Specifically crafted OPC UA m...
[]
null
null
9.8
null
ICSA-21-315-04
Siemens Mendix
Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache.
[]
null
4
null
null
ICSA-20-056-01
Moxa MB3xxx Series Protocol Gateways
Two separate issues cause a buffer overflow in the built-in web server that may allow a remote attacker to initiate a DoS attack and execute arbitrary code.CVE-2019-9099 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A...
[]
null
null
5.3
null
ICSA-20-289-02
Advantech R-SeeNet
The R-SeeNet webpage suffers from SQL injection, which allows a remote attacker to invoke queries on the database and retrieve sensitive information.CVE-2020-25157 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
7.5
null
ICSA-23-353-03
EFACEC UC 500E
An attacker with network access could perform a man-in-the-middle (MitM) attack and capture sensitive information to gain unauthorized access to the application. An attacker could construct a URL within the application that causes a redirection to an arbitrary external domain and could be leveraged to facilitate phishi...
[]
null
null
4.1
null
ICSA-23-033-01
Delta Electronics DIAScreen
Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.-CVE-2023-0250 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:...
[]
null
null
7.8
null
ICSA-19-283-02
Siemens PROFINET Devices (Update K)
An unauthenticated attacker sending a large amount of specially crafted UDP packets may trigger a denial-of-service condition. CVE-2019-10936 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
7.5
null
null
ICSA-20-294-02
Hitachi ABB Power Grids XMC20 Multiservice-Multiplexer
A vulnerability exists in a specific library included in these products. An attacker could exploit the vulnerability by sending a specially crafted message to the XMC20 node to open a communication channel without first performing authentication, resulting in unauthorized access.CVE-2018-10933 has been assigned to this...
[]
null
null
9.1
null
ICSMA-19-248-01
BD Pyxis (Update A)
A vulnerability has been identified where existing access privileges are not restricted in coordination with the expiration of access based on active directory user account changes when the device is joined to an AD domain. CVE-2019-13517 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been cal...
[]
null
null
7.6
null
ICSMA-22-006-01
Philips Engage Software
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data.CVE-2021-23173 has been assigned to this vulnerability. A CVSS v3 base score of 2.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:N/A:N).
[]
null
null
2.6
null
ICSA-21-313-03
Siemens Nucleus RTOS TCP/IP Stack
ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004) The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a use...
[]
null
7.5
null
null
ICSA-21-138-01
ICSA-21-138-01_Emerson Rosemount X-STREAM
The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access.CVE-2021-27457 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S...
[]
null
null
5.4
null
ICSA-22-307-02
Nokia ASIK AirScale System Module
A vulnerability exists in Nokia 's ASIK AirScale system module (versions 474021A.101 and 474021A.102) that could allow an attacker to place a script on the file system accessible from Linux. A script placed in the appropriate place could allow for arbitrary code execution in the bootloader.CVE-2022-2482 has been assign...
[]
null
null
8.4
null
ICSA-22-251-01
MZ Automation libIEC61850
The affected product does not sanitize input before memcpy is used, which could allow an attacker to crash the device or remotely execute arbitrary code.CVE-2022-2970 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H...
[]
null
null
8.6
null
ICSA-22-055-02
Mitsubishi Electric EcoWebServerIII
Multiple vulnerabilities due to cross-site scripting exist in Energy Saving Data Collecting Server (EcoWebServerIII), which may result in information disclosure or information tampering of the product.CVE-2016-10735, CVE-2018-14040, CVE-2018-14042, CVE-2018-20676, CVE-2019-8331, CVE-2020-11022, and CVE-2020-11023 have ...
[]
null
null
7.5
null
ICSA-18-284-03
Delta Industrial Automation TPEditor
Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files lacking user input validation before copying data from project files onto the stack and may allow an attacker to remotely execute arbitrary code.CVE-2018-17929 has been assigned to this vulnerability. A C...
[]
null
null
6.6
null
ICSA-23-192-01
Rockwell Automation Enhanced HIM
The API the application uses is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a...
[]
null
9.6
null
null
ICSA-23-348-13
Siemens SICAM Q100 Devices
The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user. Affected devices are missing cookie protection flags when using the ...
[]
null
5.5
null
null
ICSA-20-224-02
Schneider Electric APC Easy UPS On-Line
A vulnerability exists when accessing a vulnerable method of `FileUploadServlet` that may lead to uploading executable files to non-specified directories.CVE-2020-7521 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H...
[]
null
null
9.8
null
ICSA-18-128-01
Siemens Medium Voltage SINAMICS Products (Update A)
Specially crafted PROFINET DCP broadcast packets could cause a Denial-of-Service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Specially crafted packets sent to port 161/udp could cause a Denial-of-Servic...
[]
null
7.5
null
null
ICSMA-21-196-01
ICSMA-21-196-01_Ypsomed mylife
The Ypsomed mylife Cloud discloses password hashes during the registration process.CVE-2021-27491 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). The Ypsomed mylife Cloud reflects the user password during the logi...
[]
null
null
5.4
null
ICSA-22-286-16
Siemens Desigo CC and Cerberus DMS
Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.
[]
null
9.8
null
null
ICSA-22-195-10
Siemens Mendix Applications
An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration.
[]
null
6.5
null
null
ICSA-23-131-14
Rockwell Automation PanelView 800
The affected product is vulnerable to an out-of-bounds write, which could allow an attacker to accomplish a heap buffer overflow if the user has the email feature enabled in the project file WolfSSL uses. This feature is disabled by default. CVE-2020-36177 has been assigned to this vulnerability. A CVSS v3 base score o...
[]
null
7.8
null
null
ICSA-19-227-03
Siemens SCALANCE Products (Update A)
An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnera...
[]
null
6.6
null
null
ICSA-22-228-04
Softing Secure Integration Server
A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server.CVE-2022-1069 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The application ...
[]
null
null
7.5
null
ICSA-23-047-12
Siemens JT Open, JT Utilities, and Parasolid
The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. The affected application contains a memory corruption vulnerability while parsing specially crafted JT files. This could allow an...
[]
null
7.8
null
null
ICSA-20-135-02
Emerson WirelessHART Gateway
There is a flaw in the code used to configure the internal gateway firewall when the gateway's VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway.CVE-2020-12030 has been assigned to this vulnerability. A CVSS...
[]
null
null
10
null
ICSA-22-083-02
mySCADA myPRO
An authenticated user may be able to misuse parameters to inject arbitrary operating system commands.CVE-2022-0999 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-22-195-14
Siemens CPC80 Firmware of SICAM A8000
When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.
[]
null
7.5
null
null
ICSA-21-287-09
Siemens SIMATIC Process Historian
An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data.
[]
null
9.8
null
null
ICSA-21-194-13
Siemens SINAMICS PERFECT HARMONY GH180 (Update A)
A remote unauthenticated attacker with network access could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. CVE-2020-15782 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/...
[]
null
null
8.1
null
ICSA-22-321-02
Cradlepoint IBR600
Cradlepoint IBR600 NCOS versions 6.5.0.160bc2e and priorare vulnerable to shell escape, which enables local attackers with non-superuser credentials to gain full, unrestrictive shell access which may allow an attacker to execute arbitrary code.CVE-2022-3086 has been assigned to this vulnerability. A CVSS v3 base score ...
[]
null
null
7.1
null
ICSA-17-262-01
PHOENIX CONTACT mGuard Device Manager
Improper Access Control vulnerabilities have been reported for Oracle Java SE, which is provided with PHOENIX CONTACT FL MGUARD DM. According to Oracle, the supported Java versions affected by these vulnerabilities are Java SE: 8u131, 7u141 and 6u151, Java SE Embedded: 8u131, and JRockit: R28.3.14. PHOENIX CONTACT prov...
[]
null
null
9
null
ICSA-24-165-14
Fuji Electric Tellus Lite V-Simulator
The affected product is vulnerable to an out-of-bounds write, which could allow an attacker to manipulate memory, resulting in execution of arbitrary code. The affected product is vulnerable to a stack-based buffer overflow, which could allow an attacker to execute arbitrary code.
[]
null
7.8
null
null
ICSA-24-275-02
Mitsubishi Electric MELSEC iQ-F FX5-OPC
A Denial-of-Service (DoS) vulnerability due to NULL Pointer Dereference when processing PKCS#12 format certificate exists in OpenSSL installed on MELSEC iQ-F OPC UA Unit. Because OpenSSL does not correctly check if a certain field in the PKCS#12 format certificate is NULL, a NULL pointer dereference occurs when the fie...
[]
null
7.5
null
null
ICSA-19-099-05
Siemens RUGGEDCOM ROX II
The shipped version of the Quagga BGP daemon (bgpd) can double-free memory when processing certain forms of UPDATE message, containing cluster-list and/or unknown attributes. A successful attack could cause a denial of service or potentially allow an attacker to execute arbitrary code. The security vulnerability could ...
[]
null
null
7.5
null
ICSA-18-282-02
Siemens SCALANCE W1750D
An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to...
[]
null
null
5.9
null
ICSMA-19-353-01
Philips Veradius Unity, Pulsera, and Endura Dual WAN Routers
The router software uses an encryption scheme that is not strong enough for the level of protection required.CVE-2019-18263 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
5.3
null
ICSMA-18-340-01
Philips HealthSuite Health Android App
The software uses simple encryption that is not strong enough for the level of protection required.CVE-2018-19001 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N).
[]
null
null
3.5
null
ICSA-19-164-01
Johnson Controls exacqVision Enterprise System Manager
By default, excessive permissions to directories are granted to authorized, low-privilege system accounts. This could be leveraged by an attacker to make application file changes or to enable privilege escalation attacks.CVE-2019-7588 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calcula...
[]
null
null
6.7
null
ICSA-21-187-01
Moxa NPort IAW5000A-I/O Series Serial Device Server
Two buffer overflows in the built-in web server may allow a remote attacker to cause a denial-of-service condition.CVE-2021-32968 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). Five buffer overflows in the bui...
[]
null
null
9.8
null
ICSMA-19-248-01
BD Pyxis (Update A)
A vulnerability has been identified where existing access privileges are not restricted in coordination with the expiration of access based on active directory user account changes when the device is joined to an AD domain. CVE-2019-13517 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been cal...
[]
null
null
7.6
null
ICSA-22-195-04
Siemens Simcenter Femap
The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17293)
[]
null
7.8
null
null
ICSA-23-208-01
ETIC Telecom RAS Authentication
ETIC Telecom RAS versions 4.7.0 and prior the web management portal authentication disabled by default. This could allow an attacker with adjacent network access to alter the configuration of the device or cause a denial-of-service condition.
[]
null
null
7.1
null
ICSA-23-080-05
VISAM VBASE Automation Base
Versions of VISAM VBASE Automation Base prior to 11.7.5 may disclose information if a valid user opens a specially crafted file. CVE-2022-41696 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). Versions of VISAM VBA...
[]
null
null
5.5
null
ICSA-23-257-03
Siemans QMS Automotive
User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users. User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impers...
[]
null
3.9
null
null
ICSA-21-131-14
Siemens SCALANCE W1750D (Update B)
A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP). A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP). A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP). A remote ex...
[]
null
6.5
null
null
ICSA-19-281-04
Siemens SIMATIC IT UADM
An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is requ...
[]
null
null
6.8
null
ICSA-19-085-03
ENTTEC Lighting Controllers
An unauthenticated user can initiate a remote reboot, which may be used to cause a denial of service condition.CVE-2019-6542 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-21-231-01
ICSA-21-231-01_AVEVA SuiteLink Server
Heap-based buffer overflow in SuiteLink server while processing commands 0x05/0x06CVE-2021-32959 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Null pointer dereference in SuiteLink server while processing comman...
[]
null
null
7.5
null
ICSA-23-299-05
Rockwell Automation FactoryTalk View Site Edition
FactoryTalk View Site Edition V11.0 insufficiently validates user input, which could potentially allow threat actors to send malicious data bringing the product offline. If exploited, the product would become unavailable and require a restart to recover resulting in a denial-of-service condition.
[]
null
7.5
null
null
ICSMA-21-012-01
SOOIL Dana Diabecare RS Products
A hard-coded physician PIN in the physician menu of the insulin pump allows attackers with physical access to change insulin therapy settings.CVE-2020-27256 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). An infor...
[]
null
null
5.7
null
ICSMA-18-142-01
BD Kiestra and InoquIA Systems (Update A)
A vulnerability in DB Manager and PerformA allows an authorized user with access to a privileged account on a BD Kiestra system to issue SQL commands, which may result in data corruption.CVE-2018-10593 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (A...
[]
null
null
6.3
null
ICSA-23-348-03
Siemens User Management Component (UMC)
When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior. A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacke...
[]
null
7.5
null
null
ICSA-23-122-01
Mitsubishi Electric Factory Automation Products
Non-transparent sharing of branch predictor within a context in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access. CVE-2022-0002 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC...
[]
null
null
8.8
null
ICSA-18-333-02
ICSA-18-333-02_Tridium Niagara Enterprise Security, Niagara AX, and Niagara 4
A cross-site scripting vulnerability has been identified that may allow a remote attacker to inject code to some web pages affecting confidentiality.CVE-2018-18985 has been assigned to this vulnerability. A CVSS v3 base score of 5.7 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N).
[]
null
null
5.7
null
ICSA-22-167-04
Siemens Mendix SAML Module
The affected module is vulnerable to XML External Entity (XXE) attacks due to insufficient input sanitation. This may allow an attacker to disclose confidential data under certain circumstances. In certain configurations SAML module is vulnerable to Cross Site Scripting (XSS) attacks due to insufficient error message s...
[]
null
7.6
null
null
ICSA-21-355-02
Horner Automation Cscape EnvisionRV
This vulnerability can be exploited by parsing maliciously crafted project files. The issues result from the lack of proper validation of user-supplied data, which can result in reads and writes past the end of allocated data structures. User interaction is required to exploit this vulnerability as an attacker must tri...
[]
null
null
7.8
null
ICSA-22-256-01
Hitachi Energy TXpert Hub CoreTec 4 Sudo Vulnerability
Sudo is included in most Linux operating systems, including in the affected product. Versions of Sudo prior to 1.9.5p2 contain an Off-by-one Error that can result in a heap-based buffer overflow, which then allows privilege escalation to root.CVE-2021-3156 has been assigned to this vulnerability. A CVSS v3 base score o...
[]
null
null
7.8
null
ICSA-22-244-01
Delta Electronics DOPSoft (Update A)
Two out-of-bounds read conditions may occur due to the affected product not properly sanitizing input while processing specific project files, which may allow unauthorized information disclosure.CVE-2022-2966 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector strin...
[]
null
null
3.3
null
ICSA-21-026-02
All Bachmann M1 System Processor Modules
The affected M-Base Controllers use weak cryptography to protect device passwords. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticat...
[]
null
null
7.2
null
ICSMA-21-187-01
Philips Vue PACS (Update B)
The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly. CVE-2020-1938 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L...
[]
null
null
2.7
null
ICSMA-19-178-01
Medtronic MiniMed 508 and Paradigm Series Insulin Pumps
The affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one...
[]
null
null
7.1
null
ICSA-19-050-04
Rockwell Automation Allen-Bradley PowerMonitor 1000 (Update A)
A remote attacker could inject arbitrary code into a targeted user 's web browser to gain access to the affected device.CVE-2018-19615 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). A remote attacker may be able ...
[]
null
null
9.8
null
ICSA-23-208-02
PTC KEPServerEX
PTC's KEPServerEX: Versions 6.0 to 6.14.263 is vulnerable to being made to read a recursively defined object that leads to uncontrolled resource consumption. KEPServerEX uses OPC UA, a protocol which defines various object types that can be nested to create complex arrays. It does not implement a check to see if such a...
[]
null
null
7.5
null
ICSA-17-241-01
AzeoTech DAQFactory
Local, non-administrative users may be able to replace or modify original application files with malicious ones.CVE-2017-12699 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N). An uncontrolled search path element vu...
[]
null
null
4.2
null
ICSA-21-280-07
FATEK Automation Communication Server
The affected product lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code.CVE-2021-38432 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/P...
[]
null
null
9.8
null